LLR 6045 with P-SH-N
- General
- Detail
- Technical Data
- Downloads
The combination of an airduct tube 6045 and a contact proof antistatic bar can be supplied in nearly all requested lengths and air volumes. The compressed air is blown out of nozzles over the full length across to the high voltage spike at an angle of 45°.
According to installation situation and air volume, the accordant airduct tube is chosen.
Function:
The positive and negative ions generated by the antistatic bar saturate the airflow coming out of the nozzles. This airflow transports the ions onto the product to be neutralized. The electrostatic charges on the product will be eliminated and depending on air pressure adherent contamination will be blown away.
Application:
Neutralization over wide distances. Low to medium cleaning.
Dimensions | 45 x 60 mm (W x H) incl. nozzle H = 78 mm |
Active length in the pattern | 19,05 mm to 6000 mm |
Nozzles | D=1,6 mm² Pattern 90 mm |
Antistatic bar | P-SH-N |
Working direction | 45° across to high voltage spike |
Accreditation | CE |
Mounting | on the backside, slot nut M8. The antistatic bar is fixed at the airduct tube with brackets. |
Pressure in bar | 1,0 bar | 2,0 bar | 3,0 bar | 4,0 bar | 5,0 bar | 6,0 bar | 7,0 bar |
---|---|---|---|---|---|---|---|
Measuring distance noise-level | |||||||
500 mm | 80 dBA | 81 dBA | 83 dBA | 85 dBA | 87 dBA | 88 dBA | 90 dBA |
1000 mm | 75 dBA | 76 dBA | 78 dBA | 79 dBA | 81 dBA | 82 dBA | 84 dBA |
1500 mm | 72 dBA | 74 dBA | 75 dBA | 77 dBA | 79 dBA | 80 dBA | 81 dBA |
Air consumption | 44 NL/min | 64 NL/min | 87 NL/min | 105 NL/min | 140 NL/min | 155 NL/min | 180 NL/min |
Download
LLR_PSHN_6045_Operatingmanual_de | 380 KB | |
LLR_PSHN_6045_Drawing | 119 KB | |
PSHN_Operatingmanual_en | 2 MB |